AC Industrial Voltage Stabilizer
Non-contact compensating AC Industrial voltage stabilizer
model :ZSBW (three phase) , ZDBW (single phase)
Advantage:
1:Wide range of voltage regulation, high precision of voltage regulation, quick response.
2:Optional Synchronous regulation/separate regulation.
3: Simplified human-machine interface.
4: Wide range of load: Be compatible with resistive, capacitive and inductive loads.
5: No additional distortion of output wave.
GET A FREE QUOTE
Non-contact Compensating AC Industrial Voltage Stabilizer
model :ZSBW (three phase) , ZDBW (single phase)
According to the change of the input voltage of the power grid line, the analog signal of the changed voltage is transformed into digital signal through sampling by the voltage detection unit, which is processed by microcomputer, preprogrammed program and prefabricated data. The intelligent control system sends commands to the optocoupler to drive the non-contact and fast electronic switching circuit to compensate the output voltage appropriately and accurately, so as to adjust the output voltage within the allowable error of accuracy, so as to achieve the purpose of automatic voltage stabilization.
Non-contact Compensating AC Voltage stabilizer
Technical data (three phase)
input |
Range |
Three phase five wire 380V ± 15% (wider range can be customized) |
frequency |
50/60HZ |
|
transport Out |
Rated voltage |
Three phase 380V |
Voltage stabilizing accuracy |
±2% |
|
response speed |
<10ms |
|
Additional voltage harmonic THD |
No additional waveform distortion (static) |
|
Efficiency |
≥98% |
|
Three phase unbalance |
Three phase voltage automatic balance |
|
Delay output |
Stabilize voltage before output (protect equipment from impact) |
|
protect |
Over voltage |
When the output phase voltage exceeds 10%, it can be set to cut off the output or uninterrupted transferring to the bypass or no action,can be set |
Under voltage |
When the output phase voltage is lower than 10%, it can be set to cut off the output or uninterrupted transferring to the bypass or no action, can be set |
|
Lack of phase |
automatic cut-off |
|
Phase sequence error |
Yes, digital phase detection technology is adopted, which is accurate and reliable, and can effectively avoid misoperation caused by harmonic interference |
|
overload |
Electronic detection, output can be cut off within 3 minutes of overload or uninterrupted transferred to the bypass, can be set |
|
Over current |
Electronic detection and circuit breaker fulfill dual protection |
|
short circuit |
Electronic detection and circuit breaker fulfill dual protection |
|
bypass |
Uninterrupted automatic bypass |
|
Display |
Voltage |
A、B、C、ΣABC three phases have true RMS touch screen display respectively |
electric current |
A、B、C、ΣABC three phases have true RMS touch screen display respectively |
|
working condition |
Voltage stabilizing state / mains state |
|
abnormal |
Overvoltage, undervoltage, overload, fuse failure, phase loss and phase dislocation |
|
operation mode |
It has two working modes: voltage stabilization and mains power |
|
Overload capacity |
1.2Times the rated current for 30 minutes |
|
interface |
The intelligent man-machine interface operation panel is convenient for setting and querying various parameters |
Performance characteristics:
Fast response |
12Bit high-speed AD acquisition, 128 wave acquisition points per cycle, digital processing and operation by single chip microcomputer, and rapid compensation by electronic module |
Multiple adjustment modes can be set |
Simultaneous regulation: when simultaneous regulation is set, AD simultaneously collects the true effective values of three-phase voltages a, B and C for average calculation, and gives instructions for compensation, which can effectively improve the imbalance of three-phase voltage |
Individual regulation: when individual regulation is set, the three-phase voltages are adjusted respectively to ensure that the three-phase voltages are within the accuracy range, especially suitable for single-phase load |
|
Automatic judgment: microcomputer automatic analysis should carry out simultaneous or individual regulation. |
|
Advanced measurement technology |
12Bit AD acquisition, digital filtering and true RMS calculation by single chip microcomputer |
Accurate control |
Perfect cooperation between large-scale programmable logic device and single chip microcomputer |
Humanized Interface |
Various indicators (output voltage, voltage stabilizing accuracy and protection function) can be set through the touch keys on the operation panel |
No distortion of output waveform |
Contactless zero crossing switch switching, same frequency, phase locking and sine wave superposition compensation principle |
Resistance to harmonic interference |
True RMS voltage detection |
Wide load range |
Resistive, capacitive and inductive loads can be adapted |
Slow start and impact resistance |
voltage stabilization first before output |
Full protection function |
In case of overvoltage and undervoltage, it can be protected within 1s or automatically switched to bypass without interruption, and has perfect phase loss, overload, short-circuit protection and sound alarm function after fault |
Voltage and current display |
The true RMS values of voltage and current are displayed on the touch screen |
Component brand:
Device name |
Manufacturer |
Device name |
Manufacturer |
Thyristor |
IR chip domestic packaging |
air switch |
Chint |
transformer |
High quality silicon steel sheet is adopted |
Control chip |
ARM |
Non-contact Compensating AC Voltage stabilizer
Technical data (Single phase):
input |
Range |
Single phase 220V ± 15% (wider range can be customized) |
frequency |
50/60HZ |
|
transport Out |
Rated voltage |
Single phase 220V |
Voltage stabilizing accuracy |
±2% |
|
response speed |
<20ms |
|
Additional voltage harmonic THD |
No additional waveform distortion (static) |
|
Efficiency |
≥98% |
|
Delay output |
Stabilize voltage before output (protect equipment from impact) |
|
protect |
Over-voltage |
When the output phase voltage exceeds 10%, it can be set to cut off the output or uninterruptedly transferring to the bypass or no action, can be set |
Under-voltage |
When the output phase voltage is lower than 10%, it can be set to cut off the output or uninterruptedly transferring to the bypass or no action, can be set |
|
Lack of phase |
automatic cut-off |
|
Phase sequence error |
Yes, digital phase detection technology is adopted, which is accurate and reliable, and can effectively avoid misoperation caused by harmonic interference |
|
overload |
Electronic detection, output can be cut off within 3 minutes of overload or uninterruptedly transferring to the bypass, can be set |
|
Overcurrent |
Electronic detection and circuit breaker fulfill dual protection |
|
short circuit |
Electronic detection and circuit breaker fulfill dual protection |
|
bypass |
Uninterrupted automatic bypass |
|
Display
|
Voltage |
True RMS LCD display |
electric current |
True RMS LCD display |
|
working condition |
Voltage stabilizing state / mains supply state |
|
abnormal |
Overvoltage, undervoltage, overload, fuse failure, phase loss and phase dislocation |
|
operation mode |
It has two working modes: voltage stabilization and mains power |
|
Overload capacity |
1.2Times the rated current for 30 minutes |
|
interface |
The intelligent man-machine interface operation panel is convenient for setting and querying various parameters |
Performance characteristics
Fast response |
12Bit high-speed AD acquisition, 128 wave acquisition points per cycle, digital processing and operation by single chip microcomputer, and rapid compensation by electronic module |
Advanced measurement technology |
12Bit AD acquisition, digital filtering and true RMS calculation by single chip microcomputer |
Accurate control |
Perfect cooperation between large-scale programmable logic device and single chip microcomputer |
Humanized Interface |
Various indicators (output voltage, voltage stabilizing accuracy and protection function) can be set through the touch keys on the operation panel |
No distortion of output waveform |
Contactless zero crossing switch switching, same frequency, phase locking and sine wave superposition compensation principle |
Resistance to harmonic interference |
True RMS voltage detection |
Wide load range |
Resistive, capacitive and inductive loads can be adapted |
Slow start and impact resistance |
It has the function of voltage stabilization before output |
Full protection function |
In case of overvoltage and undervoltage, it can be protected within 1s or automatically switched to bypass without interruption, and has perfect phase loss, overload, short-circuit protection and sound alarm function after fault |
Voltage and current display |
True RMS LCD display of voltage and current respectively |
Component brand
Device name |
manufactor |
Device name |
manufactor |
Thyristor |
IR chip domestic packaging |
air switch |
chint |
transformer |
High quality silicon steel sheet is adopted |
Control chip |
ARM |
Application fields:
1: Communication station
2: Radio and television transmitting station
3: Aerospace industry
.
Please give us a message for your enquiry . order or advice. Thanks a lot.